Diffusion-open, weldable roofing underlay membrane strips
Advantages
- Reliable seam tightness: homogeneously weldable as part of the SOLITEX WELDANO 3000 system
- Can be used flexibly: also suitable for large counter battens
- Easy to work with: robust with extremely high tear-resistance
- Protects structural elements against dampness: diffusion-open, rainproof against driving rain, and hail-resistant
- Can be easily adapted using a knife or scissors
Areas of application
For reliable sealing around counter battens as part of the SOLITEX WELDANO 3000 system.
Technical specs
Material | |||
Membrane, both sides | Polyurethane | ||
Substructure fleece | Polyester | ||
Property | Regulation | Value | Regulation |
Colour | blue | ||
Surface weight | EN 1849-2 | 330 g/m² ; 1.08 oz/ft² | EN 1849-2 |
Thickness | EN 1849-2 | 0.8 mm ; 31 mils | EN 1849-2 |
Water vapour resistance factor µ | EN ISO 12572 | 225 | EN ISO 12572 |
sd value | EN ISO 12572 | 0.18 m | EN ISO 12572 |
g value | 0.9 MN·s/g | ||
Vapour permeance | ASTM E 96 | 18.2 perms | ASTM E 96 |
Fire rating | EN 13501 | E | EN 13501 |
Outdoor exposure | 4 months | ||
Hail impact resistance class (Switz.) | VKF / AEAI | HR 5 / watertightness test passed | VKF / AEAI |
Driving rain test | TU Berlin, GHS | passed | TU Berlin, GHS |
Minimum roof pitch | 3° | ||
Water column | EN ISO 811 | > 4 000 mm ; > 13' 1" | EN ISO 811 |
Watertightness, non-aged/aged* | EN 13859-1 / EN 1928, GHS | W1 / W1+ | EN 13859-1 / EN 1928, GHS |
Tensile strength MD/CD | EN 13859-1 (A) | 320 N/5 cm / 400 N/5 cm ; 37 lb/in / 46 lb/in | EN 13859-1 (A) |
Tensile strength MD/CD, aged* | EN 13859-1 (A) | 275 N/5 cm / 320 N/5 cm ; 31 lb/in / 37 lb/in | EN 13859-1 (A) |
Elongation MD/CD | EN 13859-1 (A) | 50 % / 70 % | EN 13859-1 (A) |
Elongation MD/CD, aged* | EN 13859-1 (A) | 50 % / 70 % | EN 13859-1 (A) |
Nail tear resistance MD/CD | EN 13859-1 (B) | 200 N / 200 N ; 45 lbf / 45 lbf | EN 13859-1 (B) |
*) Durability after artificial ageing with 5,000 h of UV ageing instead of 336 h | EN 1297 / EN 1296 | passed | EN 1297 / EN 1296 |
Flexibility at low temperature | EN 1109 | -20 °C ; -4 °F | EN 1109 |
Abrasion-resistance | GHS | passed | GHS |
Temperature resistance | permanent -40 °C to 100 °C ; -40 °F to 212 °F | ||
Thermal conductivity | 0.04 W/(m·K) ; 0.3 BTU·in/(h·ft²·°F) | ||