Medium-weight roofing underlay, with self-adhesive strips

Variant without self-adhesive zones

Advantages

  • Flexible planning of construction schedules thanks to 4 months of outdoor exposure
  • Ensures reliable building components: highly diffusion-open and maximum protection against driving rain and hail
  • Dry building components: pore-free TEEE functional membrane actively transports moisture to the outside
  • Permanent protection thanks to the high resistance to ageing and heat of the TEEE membrane
  • Reliable during the construction phase: suitable as a temporary covering during the construction period
  • Quick and reliable adhesion thanks to the integrated ‘connect’ self-adhesive strips on the long edges of the membrane

Areas of application

For use as a diffusion-open roofing underlay on roof sheathing, MDF and wood-fibre underlay panels, and over all mat or panel-shaped thermal insulation materials.

Planning and construction guidelines

Areas of application

The membranes in the SOLITEX MENTO series, SOLITEX UD and SOLITEX PLUS can be used as roofing underlay membranes and as temporary coverings. They stop cold external air from flowing through the building structure and ensure that the thermal insulation works in an optimal manner.

  • For ventilated steep roofs – see applicable national regulations for permissible roof pitches
  • Freely hanging or else installed directly onto even subsurfaces such as all mat or panel-shaped thermal insulation materials, wood-based panels or solid-wood boarding, for example
  • Suitable as a temporary covering during the construction phase in accordance with the applicable national regulations
  • If blown-in insulation materials are used, use of a reinforced SOLITEX roofing underlay is recommended

Use as a temporary covering

SOLITEX MENTO membranes can be used as temporary covering for up to 6 months to protect the building structure during the construction phase. The minimum pitch for the use of SOLITEX MENTO membranes is stipulated by national regulations in certain cases. For further information, please contact the pro clima partner in the country where the membranes are to be used. System adhesive tapes and adhesives should be used to stick overlaps and joints.

  • The ‘connect‘ variants have two self-adhesive strips for reliable exterior sealing.

Dark marks may form on the membrane as a result of rainwater. These have no influence on the high level of watertightness and the effectiveness of the interior membrane.

Retrofitting roofing underlay

If there was previously no roofing underlay, SOLITEX roofing underlays can be retrofitted from the inside. Roof structures without underlay and thus without a counter-batten plane are often encountered on existing buildings. If insulation is to be fitted on these structures, it is recommended to first retrofit an exterior insulation-protection layer to improve the reliability of the structure.

No rear ventilation of the insulation layer is necessary

Roofing underlay membranes make rear ventilation of thermal insulation materials unnecessary. pro clima SOLITEX roofing underlay membranes can be installed directly onto the thermal insulation in all cases, i.e. the insulation material can fill the full depth of the rafters.
In the case of non-insulated attics, it is advantageous to provide hip and ridge ventilation in order to ventilate the attic space. Complicated and frequently ineffective ventilation features on the eaves, ridge, valley, hip and roof fittings are thus not necessary.

Increased indoor humidity

These highly permeable membranes allow moisture to dry out of the structure to the outside more easily and more quickly. This is advantageous both during the construction phase and during normal use (if moisture contained in the indoor air penetrates into the structure by diffusion or convection).

As a rule, moisture that arises due to construction work should be able to escape the building structure quickly by ventilation through open windows. Dryers can help to speed up the drying process in wintertime. This helps to avoid permanently high levels of relative humidity.

No ‘tent effect’

Pore-free SOLITEX membranes offer particularly good watertightness against driving rain. The membrane can be installed over the surface of insulation materials or onto the roof sheathing. A tent effect is reliably prevented by the monolithic functional film and the multi-layer structure. The term ‘tent effect’ describes the phenomenon whereby waterproof tent sheets allow large amounts of moisture into tents at points where they are in contact with inside objects.

Rainproof roofing underlays

These membranes may be used as temporary coverings and additional rain-protection measures, in accordance with the locally applicable regulations.

Approval and composition

The special membranes in the SOLITEX roofing underlay series are made of a thermoplastic elastomer ether-ester; the protective and covering fleeces are made of polypropylene.

All SOLITEX membranes have been tested in accordance with the requirements of EN 13859-1. They have the CE label.

Technical support

If you have questions on applications, please contact pro clima Technical Support.



Building projects with SOLITEX MENTO